Linum Catalogus

84 ©Linum Montagesokkels & dakdoorvoeren Alixo Safe Access - Plant Deck Frame Plant Deck Frame - maatwerk • Ontworpen om de toegang tot meerdere VRV/VRF installaties te vergemakkelijken • Wijde basis zorgt voor extra stabiliteit op plaatsen waar veel wind is • Anti-slip oppervlak van het rooster • Snelle installatie • Veilig en duidelijk pad dankzij gele kleur A ( 1:20 ) CANTILEVER STEP Frame Weight Design Load Z Y X No. of Part Nu Height Overall Len Overall Wid Distance Betwe Descri M GR Part/ 1 1 2 2 3 3 4 4 A B C D PROJECT REF: UNIT REF: TIT DW BF A3 SCALE: DIMENSIONS IN mm U.O.S TOLERANCES: 0.0 ± 0.5mm U.O.S SHEET 1 OF 2 DATE: DRAWN: CHECKED: REV Installation and application considerations should include health, safety and enviromental needs, regulations and standards, codes of practice, climate conditions, installation location, product orientation, evaluation of the roof structure, composition, surface and condition, ancillary and complimentary products andmaterials. Big Foot Systems recommend that all rooftop products are handled and installed by suitably qualified persons. All scheme designs are based on the use of Big Foot Systems' products andmaterials only. Terms and conditions available on request 1:20 FOOT PRESSURE: UDL: Plant Deck Frame N/A N/A N/A A SIMMANS A Material grade: BS EN 10219-1:2006 (S235JR). Welding standard: BS EN ISO 15614-1. Galvanizing standard: BS EN ISO 146 Reference specification document "Custom Fabrication Specification" (BF-SPEC-050411) for further information Reference specification document "Big Foot Systems Cross Bar Specification (BF-SPEC-230610) for further informatio 12/05/2016 S BIRCH Pl A Design load based on maxim Foot's Technical Office is ab therefore higher loads may Allowable foot pressure will spacings are adjustable to a Working conditions: Suitabl temperatures between -40  Y X Z B4040 B4080 B4060 380 - 480 A ( 1:20 ) CANTILEVER STEP Frame Desi Z Y X Heigh O O Distan 1 1 2 2 3 3 4 4 A B C D PROJECT REF: UNIT REF: A3 SCALE: DIMENSIONS IN mm U.O.S TOLERANCES: 0.0 ± 0.5mm U.O.S SHEET 1 OF 2 DATE: DRAWN: CHECKED: REV Installation and application considerations should include health, safety and enviromental needs, regulations and standards, codes of practice, climate conditions, installation location, product orientation, evaluation of the roof structure, composition, surface and condition, ancillary and complimentary products andmaterials. Big Foot Systems recommend that all rooftop products are handled and installed by suitably qualified persons. All scheme designs are based on the use of Big Foot Systems' products andmaterials only. Terms and conditions available on request 1:20 FOOT PRESSURE: UDL: Plant Deck Frame N/A N/A N/A A SIMMANS A Material grade: BS EN 10219-1:2006 (S235JR). Welding standard: BS EN ISO 15614-1. Galvanizing standard: BS Reference specification document "Custom Fabrication Specification" (BF-SPEC-050411) for further inf Reference specification document "Big Foot Systems Cross Bar Specification (BF-SPEC-230610) for furthe 12/05/2016 S BIRCH A Design load based Foot's Technical O therefore higher lo Allowable foot pre spacings are adjus Working condition temperatures betw Y X Z B4040 B4080 B4060 380 - 480 B4040 B4060 B4080 4 unit 6 unit 8 unit 6 8 10 mm 2436 3436 4436 inches 95 14/16 135 4/16 174 10/16 mm 3450 3450 3450 inches 135 13/16 135 13/16 135 13/16 mm 485 495 500 inches 19 2/16 19 8/16 19 11/16 mm 380 380 380 inches 14 15/16 14 15/16 14 15/16 mm 480 480 480 inches 18 14/16 18 14/16 18 14/16 kg 230 320 410 lbs 507 705 904 kg 1600 2400 3200 lbs 3527 5291 7055 Plant Deck Frame Frame Weight Design Load Max Min Z Y X No. of feet Part Number Height Overall Length Overall Width Distance Between Feet Description kg/m3 lbs/ft3 Foot Nylon GF-30% 1140 71 Mat Rubber BS7188:1989 650-1020 41-64 Metalwork Galvanised Steel ASTM-A36 BS EN ISO1461:1999 7800 487 GRP Grating GRP BS 4592-6:2008 1500-1700 94-106 Material Specification Part/Description Material Regulation Conformance Density 2 2 3 3 4 4 5 5 6 6 A B C D TITLE: DWGNo. THISDRAWING IS COPYRIGHT AND THE PROPERTYOF BIG FOOT SYSTEMS LIMITED BFP-PDF.dwg A3 SCALE: DIMENSIONS INmmU.O.S TOLERANCES: 0.0± 0.5mmU.O.S SHEET 1 OF 1 DATE: DRAWN: CHECKED: REV allation and application considerations include health, safety and enviromental ds, regulations and standards, codes of actice, climate conditions, installation n, product orientation, evaluation of the f structure, composition, surface and on, ancillary and complimentary products materials. Big Foot Systems recommend t all rooftop products are handled and talled by suitably qualified persons. All designs are based on the use of Big Foot ystems' products andmaterials only. ms and conditions available on request 1:20 A SIMMANS A Material grade: BS EN 10219-1:2006 (S235JR). Welding standard: BS EN ISO 15614-1. Galvanizing standard: BS EN ISO 1461:2009 Reference specification document "Custom Fabrication Specification" (BF-SPEC-050411) for further information Reference specification document "Big Foot Systems Cross Bar Specification (BF-SPEC-230610) for further information 12/05/2016 S BIRCH Plant Deck Frame Product Information Sheet X Y Z POKE FRAME ELINES mm SUIT CATIONS Design load based on maximum allowable deflection on cross members when distributed across the bar. Big Foot's Technical Office is able to analyse deflection and bending stress based on specific load locations and therefore higher loads may be suitable. Allowable foot pressure will be subject to roof build-up, typically detailed by a structural engineer. Cross bar spacings are adjustable to accomodate various unit sizes. Working conditions: Suitable for internal or external applications in temperatures between -40  C to +80  C Maatwerk : consulteer ons voor meer info Uw service partner voor : Windbelasting Gedetailleerde drukberekening Technisch advies rond constructie & keuze daktype Veilige werkomgeving Alixo Safe Access - Crossgrip Crossgrip TPO • Speciaal gemaakt om platte daken (dakmembraan) te beschermen tegen onder andere gevallen werkgereedschappen en onderhoudsmateriaal • Anti-slip oppervlak (gele kleur) voor uitstekende veiligheid in alle weersomstandigheden • Stabiel bij hoge windsnelheden • Het duurzaam, UV-resistent materiaal (flexibel TPO) past perfect op elke dakstructuur • Snelle en eenvoudige installatie • Geen bevestigingsmaterialen nodig: kan los gelegd worden op het dakmembraan • Uitstekende drainage • Flexibel formaat: geleverd in rollen van 10 meter Art. nr. Afmetingen (H x B) Materie Gewicht Meter/rol (m) ALX-1950 12 x 600 mm TPO 5,2 kg/m² 10 Maatwerk : consulteer ons voor meer info

RkJQdWJsaXNoZXIy MzgyMTg=