Linum Catalogus

76 ©Linum Montagesokkels & dakdoorvoeren Multi Foot - Polyamide • Rechthoekige PA stelpoten voor diverse toepassingen: kabelgoten, buisstructuren (buis 41 x 41 mm), draadstangen (M10), ... • Beide ”Multi Foots” worden geleverd met een geïntegreerde anti-vibratiemat • Snelle en eenvoudige installatie • Profielen of draadstangen niet inbegrepen Art. nr. Omschrijving Afm. voetvlak St/doos BFF-2061 Multi Foot 400 400 x 180 4 BFF-2011 Multi Foot 600 600 x 220 3 MULTIFOOT 400 INTEGRATEDMAT MULTIFOOT 400 BRUFMA)OFANACCEPTABLE LOADOF 35KN/M2 (5.1PSI).PROJECTSPECIFICDESIGNPARAMETERS 4 2.0 WWW.BIGFOOTSUPPORT.COM TECHNICAL@BIGFOOTSUPPORT.COM BIGFOOTTECHNICALOFFICE FORBESPOKEDESIGNSPLEASECONTACTTHE +44(0)1323844355 2.0 2.0 3 3 1.2 2.5 4.6 1.7 2.5 5 2.6 5.5 10.1 3.7 5.5 82 128 134 259 474 181 282 295 571 1045 OTDETAILS&PERFORMANCERECOMMENDATIONS 37 B9043 B9045 B9368 B6357 B6359 OT1000 FIX-ITFOOTLOW250 FIX-ITFOOTLOW400 FIX-ITFOOTLOW500 MULTIFOOT400 MULTIFOOT600 0 250 400 500 400 600 2 10 16 193/4 16 24 130 130 130 180 220 5 5 5 7 83/4 50 50 50 80 80 ENGTH (@ m/min) YIELDSTRENGTH COMPRESSIVE STRENGTH (@20%) psi MPa psi MPa psi - - - 1.20 174 30458 250 36259 - - - 145 21030 - - F 4 5 C D 4 6 7 8 A B FIX-IT /MULTIFOOTSPECIFICATIONSHEET 5 6 7 8 E THEPROPERTYOFBIGFOOTSYSTEMSLIMITED TITLE: DWGNO. THISDRAWING ISCOPYRIGHTAND FM1005-01-01 Geïntegreerde anti-vibratiemat Ideaal voor projecten met kabelgoten, draadstangen (M10), buisstructuren (41 x 41 mm), ... Big Foot Systems - Multi Foot & Stand Range 1 1 2 2 3 3 4 4 5 5 6 6 A A B B C C D D PROJECT REF: UNIT REF: TITLE: DWGNo. THISDRAWING IS COPYRIGHT AND THE PROPERTYOF BIG FOOT SYSTEMS LIMITED BFT-MFO.dwg A3 SCALE: DIMENSIONS INmmU.O.S TOLERANCES: 0.0± 0.5mmU.O.S SHEET 2 OF 2 DATE: DRAWN: CHECKED: REV Installation and application considerations should include health, safety and enviromental needs, regulations and standards, codes of practice, climate conditions, installation location, product orientation, evaluation of the roof structure, composition, surface and condition, ancillary and complimentary products andmaterials. Big Foot Systems recommend that all rooftop products are handled and installed by suitably qualified persons. All scheme designs are based on the use of Big Foot Systems' products andmaterials only. Terms and conditions available on request 1 : 5 FOOT PRESSURE: UDL: Multi Foot N/A N/A N/A NWOOD A Material grade: BS EN 10219-1:2006 (S235JR).Welding standard: BS EN ISO 15614-1.Galvanizing standard: BS EN ISO 1461:2009 Reference specification document "Custom Fabrication Specification" (BF-SPEC-050411) for further information Reference specification document "Big Foot Systems Cross Bar Specification (BF-SPEC-230610) for further information 14/02/2017 A SIMMANS Multi Foot Technical Data Sheet 400 180 220 600 40 260 260 40 102 42 21 102 42 21 125 150 125 B9655 B9640 41 41 MULTI FOOT WILL ACCOMODATE: 41x41 UNISTRUT (VERTICALLY) 41x21 UNISTRUT (HORIZONTALLY) 40x20 CHANNEL (HORIZONTALLY) 10mm/12mm THREADED ROD (VERTICALLY) B9655 B9640 1 1 2 2 3 3 4 4 5 5 6 6 A A B B C C D D PROJECT REF: UNIT REF: TITLE: DWGNo. THISDRAWING IS COPYRIGHT AND THE PROPERTYOF BIG FOOT SYSTEMS LIMITED BFT-MFO.dwg A3 SCALE: DIMENSIONS INmmU.O.S TOLERANCES: 0.0± 0.5mmU.O.S SHEET 2 OF 2 DATE: DRAWN: CHECKED: REV Installation and application considerations should include health, safety and enviromental needs, regulations and standards, codes of practice, climate conditions, installation location, product orientation, evaluation of the roof structure, composition, surface and condition, ancillary and complimentary products andmaterials. Big Foot Systems recommend that all rooftop products are handled and installed by suitably qualified persons. All scheme designs are based on the use of Big Foot Systems' products andmaterials only. Terms and conditions available on request 1 : 5 FOOT PRESSURE: UDL: Multi Foot N/A N/A N/A NWOOD A Material grade: BS EN 10219-1:2006 (S235JR).Welding standard: BS EN ISO 15614-1.Galvanizing standard: BS EN ISO 1461:2009 Reference specification document "Custom Fabrication Specification" (BF-SPEC-050411) for further information Reference specification document "Big Foot Systems Cross Bar Specification (BF-SPEC-230610) for further information 14/02/2017 A SIMMANS Multi Foot Technical Data Sheet 400 180 220 600 40 260 260 40 102 42 21 102 42 21 125 150 125 B9655 B9640 41 41 MULTI FOOT WILL ACCOMODATE: 41x41 UNISTRUT (VERTICALLY) 41x21 UNISTRUT (HORIZONTALLY) 40x20 CHANNEL (HORIZONTALLY) 10mm/12mm THREADED ROD (VERTICALLY) B9655 B9640 Alle afmetingen in mm Mini Split Stand Range • Met universele 41 x 41 mm dwarsverbinder voor flexibele bevestiging van standaard inlegmoeren • Uitvoering in hoogte 305 mm op voeten van 200 x 200 mm • Lengte dwarsverbinder: 990 mm • Anti-vibratie bevestigingsschroeven • Op vraag: aanbouwmogelijkheden met een extender frame Art. nr. Omschrijving Afm. voetvlak Draagkracht Gewicht BFS-2001 Big Foot Mini Split Low Stand Range 700 x 1125 x 305 (LxBxH) 200 x 200 175 kg 20 kg Stand Range • Modulair grondmontagesysteem • Voor montage van verschillende type units • Voeten uitgerust met uitsparingen voor extra bevestiging in de bodem • Niet geschikt voor installaties op platte daken (in volle windbelasting) • Warm verzinkt staal • Instelbare positie van de dwarsverbinder • Snelle, lichte en eenvoudige montage • Frames met extra lange dwarsverbinders voor VRV/VRF op vraag beschikbaar VRV/VRF Stand Range • Met universele 41 x 41 mm dwarsverbinder voor flexibele bevestiging van standaard inlegmoeren • Uitvoering in hoogte 305 mm op voeten van 200 x 200 mm • Lengte dwarsverbinder: 990 mm • Op vraag: aanbouwmogelijkheden met een extender frame • Volledige klemkit inbegrepen Art. nr. Omschrijving Afm. voetvlak Draagkracht Gewicht BFS-2100 Big Foot VRV/VRF Stand Range 1230 x 1360 x 305 (LxBxH) 200 x 200 600 kg 35 kg BFS-2001 BFS-2100

RkJQdWJsaXNoZXIy MzgyMTg=